Our Services
Our Services
我们的服务:行业 > > Lamps standard
Lamps standard
Lamps standard

First, Scope

  This standard specifies the technical requirements of the LED lamps, experimental methods, inspection rules, marking, packing, transport and storage conditions.

  LED lighting refers to the lighting of the LED as a light-emitting device, and high pressure sodium lamps, metal halide lamps for the light source compared to conventional lighting with energy-saving, environmental protection, long life and other advantages.

  Second, the reference:

  The GB7000.1-2002D of the General safety requirements and tests for luminaires

  The measurement method of the integral LED lamp

  Of the GB4028-93 the protection provided by enclosures IP code

  Third, the test project:

  Electrical property parameters:

  B ⑴ operating voltage operating current c d power factor ⑸ lamp security

  Optical properties:

  ⑴ intensity: light intensity distribution curve, the intensity curve.

  ⑵ luminous flux: the total effective luminous flux, luminous flux, luminous ring of forms, luminous table.

  C light: illuminance distribution, luminance curve.

  C light source: light source number, source type, source, and encapsulation.

  D color temperature.

  ⑸ lighting angle.

  Structure and appearance:

  ⑴ housing structure material weight of the type c lamp b lamp d lights label ⑸ lamp protection levels.

  Reliability:

  ⑴ experimental c vibration experiment of temperature-rise experiment b switch d light maintenance properties and aging. ⑸ lamp function.

  Four, testing Description:

  Electrical parameters:

  ⑴ external power control DC powered lighting: voltage, ampere meter, measurement of voltage and current. (Note: measurement current measurement LED single lamp and a single color of the current record)

  B exchange of built-in power control lamp: digital power meter lamps, voltage, current, power, power factor and other parameters.

  C I kind of lamps must do dielectric strength, leakage current and insulation resistance test. Dielectric strength is 220V Terminal housing 1500V,1MIN breakdown phenomenon. Leakage current is less than 1.0MA. Insulation resistance ≥ 2M.

  D lighting level of security can be divided into four types:

  Class 0 luminaires: no ground lights, rely on basic insulation as protection against electric shock lamps. This means that easy touch conductive parts of the lamp are not connected to the protective conductor in the fixed-line facilities, in case of insulation failure, had to rely on the environment.

  Class I luminaires: ground lighting, luminaire protection against electric shock not only basic insulation, but also include additional safety measures, namely facilities easy to touch conductive parts connected to the protective earth conductor in the fixed-line, easy to touch conductive parts in the event of insulation failure without charge.

  Class II luminaire: no ground lighting, protection against electric shock not only basic insulation, but also has additional safety measures, such as double insulated or strengthened, but no protective earthing or dependent on installation conditions.

  Class III lights: protection against electric shock depends on the supply voltage for safety extra low voltage (effective value of AC voltage less than 50V), and does not generate a higher than SELV voltage lamps.

  Optical performance parameters:

  ⑴ intensity CD: light intensity distribution curve, strong curve, distribution Photometer measurements of light intensity distribution data tables are available.

  ⑵ luminous flux, LM: total luminous flux, effective luminous flux spectrum analysis system test data shall prevail. Ring of regional forms, luminous flux flux available distribution Photometer measurements.

  ⑶ illuminance LUX illumination distribution, luminance curve available distribution Photometer measurements.

  D k color temperature: available spectrum measurement system.

  Structural appearance:

  ⑴ Shell structural materials are copper, stainless steel, iron, aluminum, plastic or other PC.

  B the types of lamps now have street lights, flood lights, down lighting, tunnel lights, bulbs, explosion-proof lamps, fluorescent lamps, etc.

  C weight weight of the lamps

  D label general lighting lamps rated voltage, power, environment temperature, IP rating, luminaire type, manufacturer, etc.

  ⑸ lamp protection levels, according to the GB4208-1993 efforts to protection class (IP code) requirements in testing whether the design meets the requirements of protection class lamp structure.

  Reliability:

  ⑴ temperature rise test at a particular temperature lamps maximum cents when measuring the temperature of a specific part, in addition to the testing requirements to test components, driver IC, lamp housing, LED (lamp base or LED heatsink) parts to a fixed measuring point. Once every 30 minutes until the measurement temperature so far, recording including time, measurement of temperature and ambient temperature.

  ⑵ switch electric experiment is the light under normal operating conditions, on and off 30 seconds 1 minute as a switch loop, this switch experiment 100 times in a row and record lamps work.

  ⑶ vibration experiment is the lamp on the vibration shaking for 30 minutes, inspection lamp part no wobbles, falls off, and whether lights are functioning.

  D by lamps in the reliability test instructions for use instructions for use inspection lamps feature.

  Five, technical requirements

  The appearance of the structure

  ⑴ appearance requirements: paint color uniformity, no holes, no cracks, no impurities. Coating must adhere to the base material. LED lighting components surface should be smooth and neat, there should be no injuries, defects such as cracks, deformation in China.

  B size: the size, the drawing requirements.

  C materials: lamps the use of material and structural design drawings to meet the requirements of the Department.

  D Assembly requirements: lamp fastening screws should be screwed on the surface, edge should be free of burrs and sharp edges, the connection should be solid and loose and, if necessary, lamp fastening, connecting and sealing requirements should conform to section 4.12 of the GB7000.1-2002.

  Environmental conditions

  ⑴ the product at a temperature of-25 ° c ~40 ° c range and reliable work.

  B product ~85 ℃-40 ℃ in temperature range and reliable storage.

  C relative humidity 95%RH and reliable work.

  D intermittent exposure to vibration condition does not jeopardize the normal operation of the product.

  ⑸ product handling during free fall are not dangerous to the normal operation of the product.

  Services at atmospheric pressure for the 86~106KPA range of products work reliably.

  A working power source.

  Rated voltage 170~260V: rated frequency, 50/60Hz

  Performance requirements

  ⑴ LED lamps need good cooling system, ensure the LED lights under normal working conditions, aluminum circuit board temperature must not exceed 65 degrees centigrade.

  ⑵ LED lamps with over-temperature protection.

  Protection circuit anomaly of ⑶ LED lamps have control, LED lights must be set with 3 c or UL or VDE certified fusing devices, when an exception is to serve as a circuit over current protection.

  Anti-LED d LED lamp should have the abnormal ability to work, LED lighting, constant current for each series group LED by an independent power, constant current circuit shall ensure the LED breakdown short circuit under exceptional conditions can operate safely, and stable current.

  ⑸ LED lamps with moisture-proof, moisture respiratory function, LED lighting plate internal circuits shall be moisture-proof handle, lights should have a waterproof breathable ventilator, ensure stable operation lamp in case of humidity can still, and heat generated by the exclusion of water vapor on its own work.

  ⑹ total downward fluxes of LED lamps and lighting energy consumption ratio ≥ 56LM/W.

  ⒌ safety requirements

  LED lamp shall conform to the requirements of GB7000.5, LED modules for general lighting shall conform to the requirements of IEC62031, LED module with AC or DC power supply electronic control devices shall conform to the requirements of IEC61347-2-13 and IEC62384.

  Electromagnetic compatibility requirements

  LED Street lamp insertion loss, disturbance voltage and radiated electromagnetic disturbances, harmonic currents shall conform to the requirements of GB17743 and GB17625.1.

  ⒎ casing protection degree

  Lamp protection levels, according to the GB4208-1993 of protection provided by enclosures (IP code) requirements in testing whether the design meets the requirements of protection class lamp structure.

  ⒏ reliability of LED lamps

  LED lamp average no fault working time shall be not less than 50,000 hours.

  ⒐ LED light source life

  LED luminaire during normal conditions of use should be greater than the average life expectancy of 50,000 hours.

  Note: the flux is lower than when I first installed 70% as the end of its useful life.

  Liu, product inspection

  The appearance of the structure checks

  ⑴ Visual inspection: Visual inspection, under appearance, the appearance requirements.

  B check: using tape or similar tools to measure, dimension, the dimension requirements provided.

  ⑶ material inspection: Visual inspection materials should comply with the material requirements of the regulations.

  D Assembly inspection: Visual inspection and, if necessary, by section 4.12 of the GB7000.1-2002 experimental checks, provisions of the Assembly, the Assembly requirements.

  Lamp performance check

  ⑴ lighting electrical products that meet the same development parameters provided by the Department.

  ⑵ lamp optical parameter conforms to the same parameter of the product development department.

  ⑶ lamp reliability test conforms to the same parameter of the product development department.

  Seven, marking, labelling and instructions for use

  Signs, labels

  Each LED lamp in a prominent position, set the label or nameplate, include the following:

  ⑴ models, standard code and product codes.

  B product name in full.

  ⑶ factory full name and trademark.

  ⑷ power factor

  ⑸ working temperature

  ⑹ IP protection class

  ⑺ rated voltage, rated current, rated correlated color temperature and luminous flux, rated life.

  Operating instructions

  Each LED lamp configuration instructions should be given to security all the information and the proper use of this equipment. The information shall include the following elements:

  ⑴ working principles block diagram

  B technical specifications

  C installation and requirements

  D security considerations

  Eight, packaging, transportation, storage

  Packaging

  ⑴ inspection before packing

  ① certificate of product and technical documentation, accessories and spare parts are complete.

  Secondly, packing list and random accessories list is complete.

  ③ the appearance without damage.

  ④ surface free of dust.

  Packaging

  Product packaging product name, model, quantity, standards, etc.

  Packaging requirements

  Have inner packing and outer packing, packaging should be dust-proof, waterproof, moisture-proof, vibration-proof, and so on.

  Transport

  Product should be suitable for land, air and sea transport. Transportation, loading and unloading operates according to the sign on the container. Products in transit, there should be no violent vibration and impact.

  ⒌ store

  LED lights when the relative humidity is not more than 70% of the Treasury stores, interior free of acids, alkalis, salts and corrosive, explosive gas and dust and snow and rain Qin suffered.